E48-G60

This steel linear rail has its length according to customer needs.

  • Load on minor axis : 240 kg
  • Load on major axis : 120 kg

Option

Pictures


3D


Option :

Description

This steel linear rail has its length according to customer needs.

It includes one or many hardened steel runners, that also contains plastic items in their construction.

Each runner has a load capacity. Increasing the number of runners increases the load capacity by the same factor.

Applications

This linear rail is designed for heavy loads in applications requiring a very small footprint, such as covers or enclosures for guard of small machine ..

Recommended operating temperatures from -20 to 100°C.

This kind of product will not slide well under torque; please ensure that the load is balanced on one or more runners, if necessary.

This product can be used as a sliding pair, guide bar or rod, suspended rail, handling rail, sliding doors horizontal slider or vertical guide.

Manufacture

Chambrelans production of this guid rail is based on the use of cold drawn stainless steel profiles.

Anti-corrosion standard coating for the rail is a silver zinc, of a 12 microns average thickness, which offers excellent resistance to the salt spray test. Runner is nitrurated.

The rail has axial pins covered with rubber at each end.

Its ball bearings are made of 100C6 chrome steel. It is greased with a high pressure grease.

Chambrelan is specialized in the design and manufacturing of telescopic slides and rails for industrial applications: reinforced slides, linear slide bearings rail, bearings guide, steel, aluminum or stainless steel sliders, partial, full or over extension, heavy duty industrial drawers...

Greasings

  • Standard slides are delivered slightly greased. We use a high pressure bearing grease for steel slides and a white grease for aluminum and stainless slides. Upon request, we can use food grease (compatible clean room) a high temperature grease a teflon free grease (for spray booths...) grease free mounting (although we do not advise this option)

Options

Manual lock

It has no lock option so far.

Surface treatment

Other treatments ensuring better corrosion resistance are also available. Do not hesitate to contact us.

A nitruration coating of the rail can be supplied, which offers, in addition to corrosion resistance, an increased resistance to hammering of ball bearings and a longer lifespan. This option can be usefull in the case of intensive use or applications subject to vibrations.

Stainless stell ball bearings mounting

It can be mounted with stainless steel balls to get a very good corrosion resistance, which in some cases can provide an economical alternative to stainless steel slides.

high temp use
  • Use in high temperature (furnace): This model can be used in high temperatures environments: up to 250°C. However, adjustments are necessary: - Additionnal play in the assembly to allow the expansion elements without blocking the slide - Use of high temperature grease - Removing of all plastic parts. These adjustments on the slides should be performed in the factory, it is important to warn us with price request or order and to allow a delay for manufacturig.

the zinc coating deteriorates above 120°C, we can offer other solutions.

Vertical mounting

This slide can be mounted vertically (guillotine).

Drilling scheme

Download

Standard closed lengths

The characteristics given on this website correspond to standard manufacture or usual requirements. Our position as a manufacturer enables us to offer great flexibility in order to meet the most specific requirements.

MeasuresLoadsRail
length
Number
of runners
Load per carrier
on major axis
Load per carrier
on minor axis
StockPlease select
Length
300
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
3003720360OK
Length
300
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
3002480240OK
Length
300
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
3001240120OK
Length
350
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
3503720360OK
Length
350
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
3502480240OK
Length
350
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
3501240120OK
Length
400
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
4003720360OK
Length
400
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
4002480240OK
Length
400
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
4001240120OK
Length
450
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
4503720360OK
Length
450
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
4502480240OK
Length
450
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
4501240120OK
Length
500
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
5003720360OK
Length
500
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
5002480240OK
Length
500
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
5001240120OK
Length
550
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
5503720360OK
Length
550
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
5502480240OK
Length
550
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
5501240120OK
Length
600
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
6003720360OK
Length
600
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
6002480240OK
Length
600
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
6001240120OK
Length
650
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
6503720360OK
Length
650
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
6502480240OK
Length
650
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
6501240120OK
Length
700
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
7003720360OK
Length
700
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
7002480240OK
Length
700
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
7001240120OK
Length
750
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
7503720360OK
Length
750
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
7502480240OK
Length
750
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
7501240120OK
Length
800
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
8003720360OK
Length
800
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
8002480240OK
Length
800
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
8001240120OK
Length
850
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
8503720360OK
Length
850
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
8502480240OK
Length
850
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
8501240120OK
Length
900
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
9003720360OK
Length
900
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
9002480240OK
Length
900
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
9001240120OK
Length
1000
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
10003720360OK
Length
1000
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
10002480240OK
Length
1000
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
10001240120OK
Length
1100
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
11003720360OK
Length
1100
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
11002480240OK
Length
1100
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
11001240120OK
Length
1200
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
12003720360OK
Length
1200
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
12002480240OK
Length
1200
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
12001240120OK
Length
1300
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
13003720360OK
Length
1300
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
13002480240OK
Length
1300
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
13001240120OK
Length
1400
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
14003720360OK
Length
1400
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
14002480240OK
Length
1400
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
14001240120OK
Length
1500
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
15003720360OK
Length
1500
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
15002480240OK
Length
1500
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
15001240120OK
Length
1600
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
16003720360OK
Length
1600
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
16002480240OK
Length
1600
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
16001240120OK
Length
1700
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
17003720360OK
Length
1700
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
17002480240OK
Length
1700
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
17001240120OK
Length
1800
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
18003720360OK
Length
1800
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
18002480240OK
Length
1800
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
18001240120OK
Length
1900
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
19003720360OK
Length
1900
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
19002480240OK
Length
1900
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
19001240120OK
Length
2000
Runners
3
Load per carrier on minor axis
120
Load per carrier on major axis
240
20003720360OK
Length
2000
Runners
2
Load per carrier on minor axis
120
Load per carrier on major axis
240
20002480240OK
Length
2000
Runners
1
Load per carrier on minor axis
120
Load per carrier on major axis
240
20001240120OK

Same models

This model has equivalent models, whose overall dimensions and the diagrams of drillings are close or identical

A question?

Contact us for more information

Copyright 2017 CHAMBRELAN - Legal terms - Sitemap